Alarms across the cloud

Abiquo 4.4 enables users to create alarms on metrics across the cloud. In particular, users can select the following objects from the cloud or infrastructure lists in order to create alarms on their metrics:

  • Infrastructure

    • Datacenters

      • Racks

        • Physical machines

          • VMs

  • Cloud virtual resources

    • Virtual datacenters

      • Virtual appliances

        • Scaling groups

        • VMs

You can use built-in or custom metrics to create alarms for VMs and scaling groups. For all other entities, you can create alarms on custom metrics.  

Scaling group metrics

In Abiquo 4.4, scaling group metrics are now separate from VM metrics. The platform still configures the same metrics used in the base VM for the scaling group, but the platform stores them with the scaling group. 

Alarm tabs

There are two new alarms tabs to replace the VM Alarms tab. Both of these tabs have expanding lists where you can select entities.

Virtual datacenters → Alarms

Infrastructure → Alarms

 

Create an alarm

To create an alarm, select an entity from the list and click + to create an alarm, then complete the dialog.

 

Field

Description

Field

Description

Entity type

Select an entity with metrics from the list on the left.

Entity name

The name of the entity

Entity label

The label of the entity, which for VMs is shown in the list on the left

Entity icon

The icon that the platform displays in the UI for VMs and virtual appliances

Name

Name of the alarm with up to 128 characters. Alarm names must be unique for each metric

Description

Description of the alarm. Used together with the alarm name and VM name to identify the alarm, for example, when creating an alert

Metric

Select one of the metrics available for the VM

Metric unit

The unit of the metric. Read only

Metric description

The description of the metric. Read only

Dimension

When the metric has multiple dimensions, optionally select one or more dimensions. For example, if a VM has multiple hard disks, then the disk read bytes metric may have a dimension for each disk

Last datapoints in period

The number of datapoints that the platform will evaluate the metric during the elapsed time.

If you request the evaluation of an alarm more frequently than metric data is collected by the platform or sent by the provider, then the alarm will not activate.

We recommend that you create alarms with longer evaluation periods, for example, an average of 10 points over the last hour, so the transmission and collection intervals will not affect the activation of the alarm.

Statistic

Statistic that the platform will use for evaluating the alarm, which can be: average, maximum, minimum, sum, count, dev

Formula

Operator that the platform will use for evaluation of the alarm, for example, greater than. Values can be: notequal, greaterthan, greaterthanorequalto, lessthan, lessthanorequalto, trendup, trenddown

Threshold

Value that the platform will evaluate the alarm against, if appropriate

 

 