  1. On the Abiquo Server, enable VM duplicate names in different datacenters. See Configure Abiquo to capture VMs with duplicate names

    Code Block
    abiquo.virtualmachine.namesperdc=true


  2. On the Remote Services server, set the NARS async pool property, which must have a value of 1. Note that this is the default value for this integration

    Code Block
    abiquo.nars.async.pool.zerto.max=1


  3. Configure the network name prefixes for DRaaS networks, for recovery and failover tests. 

    1. Configure the prefix of the name of the vCenter network that recovered VMs will use. In . For a test environment where you are only using DRaaS with one enterprise, you can create a network in vCenter with this name for the enterprise and create matching external network in Abiquo.

      Code Block
      abiquo.draas.recovery.network.name=Draasnet

      If you are using DRaaS with more tenants, in Abiquo you must create an external network for each enterprise to match one in the recovery vCenter with a name such as DraasnetEnterprise1. The first part of the network name is this property's value, and the second part is the value of an enterprise property with a key of "DR-code". 

      Code Blockabiquo.draas.recovery.network.name=Draasnet

    2. Configure the default network used for failover tests by the DRaaS provider. The naming convention is the same as for the recovery network. 

      Code Block
      abiquo.draas.recovery.testnetwork.name=DraasTestnet
      


  4. Optionally configure recovery host details

    1. Default host name where the selected VMs will be recovered by the DRaaS provider. Accepts wildcard(*) to match any string

      Code Block
      abiquo.draas.recovery.cluster.name=*Cluster*


    2. Default datastore name that the VMs will use when recovered by the DRaaS provider.  Accepts wildcard(*) to match any string

      Code Block
      abiquo.draas.recovery.datastore.name=*datastore-local*


    3. Default folder name where the selected VMs will be recovered by the DRaaS provider. Accepts wildcard(*) to match any string

      Code Block
      abiquo.draas.recovery.folder.name=/


  5. Optionally configure protection group defaults (question)(question) – could they manually set other values?
    1. Set default priority for the protection groups. This property can have the following values: Low, Medium, High.

      Code Block
      abiquo.draas.pg.priority=Medium


    2. Set default journal history for the protection groups in hours

      Code Block
      abiquo.draas.pg.journalhistory.hours=24


    3. Set default recovery point objective for the protection groups in hours

      Code Block
      abiquo.draas.pg.rpo.seconds=180


  6. Optionally configure the delay between synchronization of DRaaS in seconds

    Code Block
    abiquo.draas.check.delay.seconds=60


...